Help Center

Follow

Inventory Scan stuck on Aborting

"How can I clear a scan status that is stuck on Aborting?" 

This is a question that we have received a few times. The problem usually occurs when communication between the console and the database break down. A quick and dirty way to clear out this problem is to delete the scan directly from the database. Go to File > Preferences > Database. Click the SQLite Console button.

You have a few options here. To clear out ALL scans that are stuck in the Aborting state run this command:

delete from computerscans where stage = 'Aborting';

If you wanted to be a little more selective and just delete the scan for a particular computer you would type this (assuming the computer name was Lebowski).

delete from computerscans where stage = 'Aborting' and computerid in (select computerid from computers where lower(name) = 'lebowski');

Note, you may need to refresh PDQ Inventory (F5) to see the cleared results.

This error is becoming less common however it still pops up from time to time.

 

 

 

Was this article helpful?
0 out of 0 found this helpful
Have more questions? Submit a request

0 Comments

Article is closed for comments.
Powered by Zendesk